M-200i System Program (Ver.1.054)
How to tell the version
Please check the version of the system working on your M-200i before downloading the archive file.
- Press [ SETUP ] to invoke the setup screen.
- Turn the [ VALUE ] knob to select "INFO," then press the [ ENTER ] button.
- INFORMATION in the display indicates the versions of your unit.
- System Version : Version of the system
- Panel Version : Firmware version of the panel unit
* Don't perform the update if the product is already up-to-date.
Version history
[ Ver.1.054 ] AUG 2019
Bug Fix
The following bug was fixed.
- Sound quality fails to be modified when the EQ library for the MTX bus is loaded.
Version compatible with M-200i RCS
For M-200i RCS, please continue to use the following versions.
- M-200i RCS Ver.1.053 for Windows
- M-200i RCS Ver.1.053 for macOS / OS X
[ Ver.1.053 ] MAY 2018
Bug Fix
The following bug was fixed.
- When an RS-232C fader control command (FDC or RFC) is used to control the MAIN bus, an error is returned even when the value is set.
[ Ver.1.052 ] MAY 2017
Bug Fix
The following bug was fixed.
- Depending on the timing of power-up, in rare cases, the L/R level balance is disrupted.
Version compatible with M-200i RCS
For M-200i RCS, please continue to use the following versions.
- M-200i RCS Ver.1.051 for Windows
- M-200i RCS Ver.1.051 for macOS / OS X
[ Ver.1.051 ] JUL 2016
Bug Fix
The following bug was fixed.
- Problems in network functioning were corrected.
- The SUBNET MASK setting for LAN cannot be set to a value other than " 255.255.255.0 ."
- The displayed value of the IP ADDRESS setting for LAN is sometimes not updated when the setting for IP ADDRESS is made.
- When a passphrase whose length is outside the standard range is entered, subsequent connection to an access point is impossible.
- After repeatedly starting and ending a Telnet connection, making a Telnet connection becomes impossible.
Functionality Improvement
- The connection stability between the M-200i and the iPad has been improved.
[ Ver.1.050 ] MAY 2016
Bug Fix
The following bug was fixed.
- RS-232C commands for gain control (PGC and PGQ) did not function correctly.
Functionality Improvements
- New library data (St.REVERB) was added to the effect library.
- MAIN send, delay switch, and delay time control commands were added to the RS-232C commands.
[ Ver.1.040 ]
Bug Fix
The following bug was fixed.
- The problem was corrected under which audio signals sent to the M-200i were not input correctly when connected as follows.
- M-200i REAC MODE: SLAVE
- M-200i at one of REAC ports 1 through 4 on the S-4000M
- S-4000S at REAC port A on the S-4000M (REAC MODE: MASTER)
Functionality Improvement
- Support for the DOCK cable (Lightning connector) has been enabled.
- Motor fader control has been improved.
[ Ver.1.030 ]
Bug Fix
The following bug was fixed.
- The problem of REAC link-up failing when REAC MODE was set to MASTER ( EXTERNAL CLOCK ) was corrected.
Functionality Improvement
- The time required for the following functions to become usable after powerup was shortened from approximately 50 seconds to approximately 20 seconds.
- Communication with an iPad over a dock cable
- Communication with an iPad over a wireless LAN
- Communication via wired LAN, RS-232C, MIDI
[ Ver.1.021 ]
Bug Fixes
The following bugs were fixed.
- When a project file is loaded, the following settings are not applied.
- Setting of DOCK L or DOCK R assigned to a channel of the input patchbay
- Output setting set to DOCK L or DOCK R of the output patchbay
- After the power is turned on, noise is produced for a moment from the input jack whose +48 V phantom power is on.
- If the following conditions are met and the [SOLO] button of M-200i itself is pressed, the cooperation between M-200i and M-200i Remote (iPad App) does not work properly.
- When M-200i Remote (iPad App) and "Sync knob and switch" are on and connected
- When "CH-SELECT FOLLOWS [SOLO]" of USER PREFERENCE of M-200i itself is on
- When the scene is recalled from M-200i RCS, the display of the current scene number of M-200i Remote (iPad App) is not changed.
[ Ver.1.020 ]
* Please read "M-200i Owner's Manual Supplement" ( M-200i_AddedFunc_e01.pdf ) for details of this software.
- S-4000M control functions have been added
From the M-200i, you can control the following functions on an S-4000M connected to the M-200i's REAC port.
- Merge Patchbay operations
- Output Patchbay operations
- Auto Map operations
- PORT 4 Split Merged Inputs operations
- Saving/Loading input/output settings files
- The REAC screen has been changed
Along with the added functionality for controlling the S-4000M, the REAC screen has changed.
Settings for the REAC mode are made at the newly added REAC MODE screen.
- V-LINK source channels have been added.
The following channels have been added to the channels that accommodate V-LINK sources.
- MAIN L/R
- AUX 1-8
- MTX 1-4
- DCA GROUP 1-8
- New functionality has been added for MIDI send.
It is now possible to send MIDI control changes during scene recall.
* This is enabled only when "FADER, MUTE CHANGE (CC)" at the MIDI SEND SETTING screen is set to ON.
[ Ver.1.010 ]
Additional Functions
* Please read "M-200i Owner's Manual Supplement" ( M-200i_AddedFunc_e01.pdf ) for details of this software.
- New functionality has been added for monitoring.
- New functionality has been added to scene memory.
- The Global Scope function
- The Recall Safe function
- New functionality has been added to the user buttons.
- MONITOR DIMMER
- EDIT GEQ
- MONITOR DIMMER
- Added the following functions for the RS-232C control.
Please refer to the "V-Mixer RS-232C Reference version 2.1 ( V-Mixer_RS-232C_v21_e01.pdf )" for detailed information.
- Control command
- Monitor dimmer on/off
- USB memory recorder transport
- USB memory recorder locate
- Song select
- Request command
- Monitor dimmer request
- USB memory recorder status request
- USB memory recorder current position request
- Song number request
- Song name request
- Recording remain time request
- DCA group operation via MIDI control change message has been added.
Please refer to "M-200i MIDI Implementation ( M-200i_MIDI_e02.pdf ) " for detailed information.
- Telnet server functions have been added.
Telnet server functions control the M-200i via a LAN (TCP/IP protocol).
Please refer to "M-200i Telnet Reference ( M-200i_Telnet_e01.pdf ) " for detailed information.
Bug Fixes
The following bugs were fixed.
- When a scene memory was recalled, some settings of the output patchbay might not be restored.
- After turning the power on, MONITOR LEVEL was always -Inf dB.
- When the REAC setting was set to SLAVE, the preamp settings of M-200i seemed to be controllable from the connected REAC device.
- When the wireless-LAN connection between an iPad and M-200i was disconnected due to the poor signal condition, reconnection by wireless LAN or DOCK cable was unable to be established.
- When the "Sync Knob and Switch" setting was ON, the change of the user fader settings from M-200i Remote was not applied soon.
How to download and expand the archive file
Download the file named "m200i_sys_v1054.zip".
It is an archive file in zip format, please double click on the file to expand. After expanding the file, the folder "m200i_sys_v1054" holding the file "M-200i.PRG" will be appeared.
How to update
Please install the system program " M-200i.PRG" to the M-200i by following the process below.
Important notice: Never turn the M-200i off during the update process, or M-200i won't reboot correctly any more.
- Put the "M-200i.PRG" at the root folder of the USB memory key.
- Insert the USB memory key to USB MEMORY connector.
- Boot the M-200i.
- In the top panel's DISPLAY section, press [SETUP] button.
- At the SETUP screen, select "SYSTEM UPDATE" and press [ENTER] button.
ARE YOU SURE
YOU WANT TO UPDATE?
|
Confirmation message will be displayed.
- Press [ENTER] button to start the update process.
NOW PROCESSING...
+*********--------------+
READING SYSTEM PROGRAM...
|
- When the following message is displayed, you will swap the USB memory key to USB WLAN ADAPTOR connector.
PLEASE INSERT THE USB MEMORY
TO USB WLAN ADAPTOR CONNECTOR.
|
- Progress message is displayed.
NOW PROCESSING...
+*********--------------+
WRITEING SYSTEM PROGRAM...
|
- At the end of the process, the message "UPDATE COMPLETED. PLEASE REBOOT." will be appeared.
UPDATE COMPLETED.
PLEASE REBOOT.
|
Now, reboot the M-200i.